The dual lumen Nasogastric/Nasointestinal Feeding Tube is designed to provide simultaneous enteral nutrition and gastric decompression, offering a comprehensive solution for critically ill patients with impaired gastrointestinal function.
Unlike conventional feeding tubes, this innovative design enables post-pyloric feeding while continuously draining gastric contents, effectively reducing reflux, abdominal distension, and aspiration risk.
Manufactured from medical-grade polyurethane, the tube ensures superior flexibility, patient comfort, and long-term tolerance. The bullet tip design facilitates smooth insertion and improves placement success rate.
The Dual Lumen Nasogastric/Nasointestinal Feeding Tube is designed to optimize enteral nutrition and gastric decompression with AOKOO’s advanced medical technology.
Designed for critically ill patients in ICU and clinical settings, the AOKOO Dual-Lumen Nasojejunal Tube provides a comprehensive solution for simultaneous enteral feeding and gastric decompression. By combining two critical therapeutic functions into one seamless, biocompatible device, AOKOO enhances patient safety, reduces nursing workload, and improves clinical outcomes.
Atraumatic Bullet-Tip: Engineered for post-pyloric success, the weighted bullet-tip facilitates smooth passage through the pylorus, increasing the first-attempt placement rate.
Simultaneous Therapy (2-in-1): Efficiently deliver enteral nutrition directly to the jejunum while performing necessary gastric decompression. This dual-action approach alleviates abdominal distension, prevents aspiration, and supports recovery for patients with complex GI needs.
Premium Hydrophilic Coating: Our proprietary hydrophilic coating on the internal lumen drastically reduces insertion friction. This ensures a smoother, more comfortable placement process, minimizing trauma to the nasal, pharyngeal, and esophageal mucosa.
Anti-Clog Technology: Featuring our signature “Smooth-Transition” junction design between the dual-lumen (gastric) and single-lumen (jejunal) sections, we eliminate internal structural inconsistencies. This prevents nutrient stagnation and clogging, ensuring long-term patency.
Simultaneous Feeding and Decompression (Core Advantage)
This dual lumen system allows:
Jejunal feeding (distal lumen)
Gastric decompression (proximal lumen)
👉 Clinical significance:
Reduces gastric distension
Prevents reflux and vomiting
Improves feeding tolerance
📌 Clinical evidence shows Dual Lumen Nasogastric/Nasointestinal Feeding Tube are effective and well tolerated in patients with obstruction or critical illness
Reduced Aspiration Risk
Feeding bypasses the stomach
Continuous drainage prevents accumulation
Ideal for ICU and high-risk patients
Advanced Dual Lumen Structure
Smooth internal transition between lumens
Prevents residue accumulation
Reduces clogging risk
👉 Similar sump/dual lumen structures are widely used for safe gastric drainage
High-Quality Polyurethane Material
Softer than PVC
Long indwelling time (up to 4 weeks in similar products)
Dual Lumen Nasojejunal Feeding Tube vs Standard NJ Tube
Feature
Dual Lumen NJ Tube
Standard NJ Tube
Feeding
Yes
Yes
Gastric Decompression
Yes
No
Aspiration Risk
Lower
Low
Patient Comfort
Higher
Moderate
Clinical Use
ICU / Obstruction
General
Q
What are the primary clinical benefits of the dual-lumen design?
A
The dual-lumen design allows for simultaneous jejunal feeding and gastric decompression. This 2-in-1 functionality enables clinicians to deliver essential nutrition to the small intestine while concurrently suctioning gastric fluids and gases. It effectively reduces abdominal distension and the risk of aspiration pneumonia in high-risk patients.
Q
How does the internal hydrophilic coating improve clinical performance?
A
Our tube features a premium internal hydrophilic coating that significantly reduces friction within the lumen. This ensures an ultra-smooth insertion process and easier guidewire removal, minimizing trauma to the nasal and esophageal mucosa while enhancing overall patient comfort during placement.
Q
Does the "Smooth-Transition" design help prevent tube clogging?
A
Yes. We use a specialized smooth-grafting process to connect the dual-lumen gastric section with the single-lumen jejunal section. By eliminating internal ridges and uneven surfaces at the junction, we prevent nutrient stagnation and crystallization, which dramatically reduces the risk of tube occlusion and ensures long-term patency.
Q
When should a dual lumen nasojejunal tube be used?
A
It is commonly used for patients who require post-pyloric feeding combined with gastric decompression, such as:
ICU or critically ill patients
Patients with gastric retention or obstruction
Post-surgical patients
Q
Is the AOKOO dual-lumen tube compatible with ENFit® safety systems?
A